What sediment looks like when you flush a tank water heater in Las Vegas

Small pale grains in shallow, cloudy water beside the end of a green hose.

By Doug Smith, DMS Plumbing, LLC

Small pale grains in shallow, cloudy water beside the end of a green hose.
Small grains are visible beside the green hose during this DMS Plumbing tank water heater flush.

Look beside the end of the green hose in my photo. See those little grains where the water gets shallow? That’s what I wanted to show you. When I tell a homeowner we flushed sediment out of a water heater, this is the part they usually don’t get to see.

You can take a hot shower every morning and have no idea what’s settling at the bottom of your tank. Here’s why I recommend a six-month flush for my Las Vegas Valley customers and what to check before you open the drain.

What is water heater sediment?

If you’ve cleaned the chalky ring out of a kettle, you’ve seen what heated water can leave behind. Calcium and magnesium make our Las Vegas Valley water hard (Southern Nevada Water Authority water quality FAQs). Inside a water heater, deposits can form on heated surfaces, and loose material can settle at the bottom as grit or flakes. In my photos, the shallow edge is where you can make out individual grains. Color alone won’t tell you exactly what they’re made of.

Cloudy flush water running along concrete beside the end of a green hose.
Flush water from the tank runs beside the hose outlet during the same flush.

What does it do to the heater?

On a gas tank, the burner heats from below. A layer of sediment along the bottom can interfere with heat transfer. Sometimes you’ll hear popping or rumbling when the burner runs. On an electric tank, deposits can collect around the lower heating element. With either type, grit can accumulate near the drain until getting water out becomes a job of its own.

Why I recommend a six-month flush

I’d rather see loose grit coming out through the hose during routine maintenance than find the drain plugged when a homeowner needs the heater serviced. For conventional residential tanks in the Las Vegas Valley, I recommend putting a flush on the calendar every six months. Check the maintenance schedule and procedure for your own model and follow the manufacturer’s instructions.

A flush carries away loose particles. Hardened deposits can remain. If the tank itself is leaking, call a plumber to inspect the leak.

How to flush a conventional residential tank water heater

Find the model number and read the “Draining and Flushing” or “Maintenance” section of your heater’s manual (examples: an A. O. Smith residential electric manual and an A. O. Smith residential gas manual). The steps below describe a common drain-and-refill method. Some models specify flushing with the cold supply open throughout. Use the procedure given for your model. Tankless heaters have a different service procedure.

  1. Find the controls and choose a suitable drain. Locate the cold-water shutoff feeding the heater and the threaded drain valve near the bottom of the tank. Use a hose rated for hot water and an approved discharge point that can handle the flow. Secure the outlet away from people and pets. If the tank is leaking, the valve is badly corroded or you can’t identify a control, call a plumber before opening anything.
  2. Turn off the heat. For an electric tank, switch off the water heater’s breaker. For gas, follow the shutdown directions on the heater and in its manual, including electrical shutdown if your model requires it. Leave the heat off during draining, flushing and refilling.
  3. Cool the stored water. With the heat off and the cold inlet still open, run a nearby hot faucet until the water runs cool. The water already stored in the tank can still scald you after the heat is turned off.
  4. Attach the hose and drain. Connect it securely to the bottom drain valve and secure its outlet at your chosen drain. For the drain-and-refill method, close the cold inlet and leave a nearby hot faucet open so air can enter. Slowly open the tank drain valve. If it sticks or water won’t flow, stop and call a plumber. Don’t force or dismantle a blocked valve on a full tank.
  5. Rinse out the loose grit. Once the tank has drained, leave the hose secured and the drain valve open. Reopen the cold supply as directed in your manual. Incoming water rinses loose material toward the drain. Watch from a safe place and continue until the discharge runs clear of visible particles.
  6. Refill and purge the air. Close the drain valve, fully open the cold inlet and leave the nearby hot faucet open. It may sputter as air escapes. Once there’s a steady stream, let it run for the purge time specified in your manual. Close the faucet and check the drain valve for drips.
  7. Restore heat after the tank is completely full. An electric element can burn out if you turn the breaker on while the element is still exposed. Confirm the tank is full and the air is out first. For gas, follow the heater’s restart instructions. As it warms up, check the valve and the area around the base for fresh water.

Write down the date while you’re standing there. Six months from now, you’ll know when it was done. If you’d like us to handle your tank water heater flush, call DMS Plumbing, LLC at (702) 353-7335. We serve the Las Vegas Valley. Nevada contractor license #0077442.